Hydrogen purification line LOV-240/200
ЛHydrogen purification line LOV-240/200 is used to purify raw hydrogen from oxygen, chlorine, nitrogen, carbon oxide and dioxide impurities and moisture; hydrogen compression to 200 kgs/sm2 and filling of gas cylinders with holding capacity up of 40 liters to the pressure of 160 kgs/sm2.
Hydrogen purification line LOV-240/200 allows simultaneous loading of up to 16 cylinders with holding capacity 40 liters to the pressure of 160 kgs/sm2.
Computer room*, m |
9 x 7 x 4,5 |
Vacuum room, m |
2 x 3 x 4,5 |
Control room, m |
4,8 x 3 x 4,5 |
Hydrogen ramp, m (open area) |
3,6 x 3,6 |
* - Premises of В1-6 class according to EIC (PUE) classification (Electrical Installation Code, Ministry of Energy of the USSR, 6th issue, 1985.
Specifications of hydrogen purification line of LOV-240/200
Parameter |
Hydrogen parameters |
Note |
|
input |
output |
||
Excess pressure, kgs/sm2 |
0,11±0,05 |
200 |
|
Flow rate, nm3/hour, not less than |
240 |
240 |
|
Gas temperature, °С, not more than |
69 |
25 |
|
Gas composition: |
|||
Hydrogen, vol.%., not less than |
91,05 |
99,999 |
|
Moisture, vol.%., not more than |
8,95 |
2,55 ppm |
Точка росы - 70 °С |
Oxygen, ppm, not more than |
300 |
1 |
|
Chlorine, ppm, not more than |
20 |
2 |
|
Nitrogen, ppm, not more than |
20 |
2 |
|
Carbon oxide and dioxide, ppm, not more than |
10 |
1 |
|
Power supply |
Value |
||
Supply voltage of the purification line |
220/380 V, 50 Hz |
||
Power consumption, KV*A, not more than |
125 |
Our company Prizma LLC can develop and manufacture hydrogen purification lines to your specifications. Please let us know the parameters (chemical analysis) of your raw hydrogen and what pressure, capacity and gas-purity value you want to receive at the output of your gas purification line.