Bell-type vacuum resistance furnace SGVE-2.4/16
Bell-type vacuum resistance furnace SGVE-2.4/16 is used in various thermal processes (annealing, sintering, etc.) at temperatures up to 1600 °С and small gas emissions where there is no interaction between the residual gases and components of the furnace in vacuum.
The furnace is designed to be used in the premises meeting the requirements of the “Interindustry labor safety rules for heat treatment of metals” POT PM RM-005-97.
Specifications of bell-type resistance furnaces SGVE-2.4/16
SGVE-2.4/16 |
|
Installed capacity, kW |
30 |
Rated capacity of the electric heaters of the furnace, kW |
30 |
Maximum temperature in the working area, °С |
1600 |
Uniformity of temperature in the working area of the furnace at maximum temperature ±, °С |
5 |
Stability of the set temperature control by the automatic heating control system ±, °С |
1 |
Furnace working area dimensions, D x H, mm |
200x400 |
Charge weight, not more than, kg |
25 |
Vacuum provided by the vacuum system in the furnace chamber, not less than, Pa (mm hg) |
1,3*10-3 (1,0*10-5) |
Temperature of external surfaces of the furnace, not more than, °С |
45 |
Rated voltage of the supply mains, V |
380/220 |
Nominal current frequency, Hz |
50 |
Number of phases of the furnace heater |
1 |
Furnace cooling water consumption, m3/hour, at pressures 2 … 3 kgs/sm2 |
2,5 |
Furnace dimensions, L x W x H, mm, not more than - furnace - control panel - transformer |
800x950x1850 645x590x1605 255x580x470 |
Furnace weight, not more than, kg - furnace - control panel - transformer |
700 120 180 |
Our company LLC Prizma can design and manufacture industrial vacuum furnaces to your specifications. Please let us know the furnace parameters you require: temperature, working atmosphere, working area dimensions, charge weight etc., and the furnace will be specially designed according to your requirements.