Regeneration unit for cylinder gas cleaners 11 ChR-4-005

Regeneration block 11ЧР-4-005 is used for regeneration gas cylinder cleaners 11ЧГМ-6-014. The unit is manufactured in a moderately cold climate modification category 2 according to GOST 15150-69. The regeneration unit for cylinder gas cleaners can be operated under a canopy or in non-explosive premises meeting the requirements of OST 11.050.003-75. The unit is powered from single-phase AC mains 220 V, 50 Hz.

Regeneration unit for cylinder gas cleaners 11 ChR-4-005 requires a supply of technical grade A hydrogen according to GOST 3022-70 at the pressure of 0.1-0.2 MPa and flow rate not less than 0.05 m3/hour, and gaseous argon according to GOST 10157-80 at the pressure of 0.1-0.2 MPa and flow rate not less than 0.02 m3/hour. It is allowed to use premium class nitrogen according to GOST 9293-74.

Regeneration unit for cylinder gas cleaners 11 ChR-4-005

Specifications of regeneration unit for cylinder gas cleaners 11 ChR-4-005

 
11 ChR-4-005
Regeneration time of a gas cylinder cleaner, hours, not more than
3
Regeneration temperature, °С
350
Dimensions, mm
652 x 300 x 500
Weight of the regeneration unit, not more than, kg
20
Power consumption, not more than, kW
2

Our company Prizma LLC can develop and manufacture other equipment similar to the existing equipment but having different parameters.