Hydrogen purification units UOGV-10, UOGV-50M1, UOGV-60

Hydrogen purification units are used to clean hydrogen from oxygen, water vapors and dust impurities. Raw gas is technical brand hydrogen according to GOST 3022-80.

Operation of the unit is based on the principle of catalytic-sorption purification of hydrogen. Hydrogen purification unit of UOGV series functions at raw gas overpressure 0.2-0.6 MPa.

Units are powered from AC mains 380/220 V, 50 Hz.

Hydrogen purification units UOGV-10, UOGV-50M1, UOGV-60

Specifications of hydrogen purification units UOGV-10, UOGV-50M1, UOGV-60

 
UOGV-10
UOGV-50M1
UOGV-60
Operating pressure, kgs/sm2
2-6
2-6
0,2-3,5
Capacity, m3/hour
10
50
60
Oxygen impurities content in the raw gas, vol.%.
1,0*10-4
1,0*10-4
1,0*10-4
Water vapors content in the raw gas, vol.%. (dew-point)
2,5*10-4 (-70 °C)
2,5*10-4 (-70 °C)
5,2*10-4 (-65 °C)
Content of dust particles 0.5 microns and larger in the raw hydrogen, particles/l
5
5
10
Power consumption, kW
3,5
5,2
12
Dimensions, mm
670 x 590 x 1850
780 x 750 x 2050
2560 x 1300 x 2800
Weight, kg
300
380
1300
Work cycle time of one line, hours
24
24
24
Regeneration time, not more than, hours
14
14
14