Hydrogen purification units UOGV-10, UOGV-50M1, UOGV-60
Hydrogen purification units are used to clean hydrogen from oxygen, water vapors and dust impurities. Raw gas is technical brand hydrogen according to GOST 3022-80.
Operation of the unit is based on the principle of catalytic-sorption purification of hydrogen. Hydrogen purification unit of UOGV series functions at raw gas overpressure 0.2-0.6 MPa.
Units are powered from AC mains 380/220 V, 50 Hz.
Specifications of hydrogen purification units UOGV-10, UOGV-50M1, UOGV-60
UOGV-10 |
UOGV-50M1 |
UOGV-60 |
|
Operating pressure, kgs/sm2 |
2-6 |
2-6 |
0,2-3,5 |
Capacity, m3/hour |
10 |
50 |
60 |
Oxygen impurities content in the raw gas, vol.%. |
1,0*10-4 |
1,0*10-4 |
1,0*10-4 |
Water vapors content in the raw gas, vol.%. (dew-point) |
2,5*10-4 (-70 °C) |
2,5*10-4 (-70 °C) |
5,2*10-4 (-65 °C) |
Content of dust particles 0.5 microns and larger in the raw hydrogen, particles/l |
5 |
5 |
10 |
Power consumption, kW |
3,5 |
5,2 |
12 |
Dimensions, mm |
670 x 590 x 1850 |
780 x 750 x 2050 |
2560 x 1300 x 2800 |
Weight, kg |
300 |
380 |
1300 |
Work cycle time of one line, hours |
24 |
24 |
24 |
Regeneration time, not more than, hours |
14 |
14 |
14 |
Our company Prizma LLC can develop and manufacture gas purification units to your specifications. Please let us know the parameters (chemical analysis) of your raw gas and what pressure, capacity and gas-purity value you want to receive at the output of your gas purification unit.